← All products

Cooling towers and evaporative equipment

CONEV · Evaporative fermentation controller

Evaporative unit to control the fermentation of red and table wines: it cools two or three musts at once with about 1/8 of the energy of a refrigeration unit.

FRIMONT CONEV evaporative fermentation controller with FRP casing and stainless-steel headers
CONEV fermentation controller.

Applications

What it solves.

The CONEV cools the musts in closed stainless-steel circuits inside an evaporative tower. It is designed for the worst ambient condition of the harvest, so capacity is guaranteed on the hottest days: in February, at full load, it works with outlet temperatures of 21 to 23 °C. On cooler days, from mid-March, capacity rises and 15 to 18 °C can be reached. It is a low investment compared with a refrigeration unit and greatly improves wine quality.

  • Fermentation temperature control for red and table wines.
  • Wineries that need to cool several tanks at the same time.
  • Support for the refrigeration plant at the peak of the harvest.

Configurations

A configuration tailored to your application.

Technical selection defines the equipment and its integration with the process.

Two or three circuits

Each circuit cools a different must, with stainless-steel thermometers at the inlet and outlet.

Construction

Fiberglass-reinforced polyester resin and stainless-steel structure. The headers can be removed to inspect and clean the heat exchanger.

Technical data

Reference values.

CONEV models

Capacity at design conditions, dimensions and circuits.

ModelCapacity (kcal/h)Capacity (kW)Length × width × height (mm)Absorbed power (HP)CircuitsFlow per circuit (l/h)
100105,0001222,000 × 1,500 × 3,7508.527,784
160160,5001872,000 × 1,500 × 3,75010.5211,898
230234,0002723,000 × 1,500 × 3,75022.5217,346
310309,1003593,000 × 1,500 × 3,750252 (3 optional)22,913
410411,0004784,000 × 1,500 × 3,75030320,311

Inlet at 30 °C and outlet at 22.9 °C, with a 19 °C design wet bulb: the average worst condition of the harvest, from February 20. With the average March wet bulb (15 °C), capacity increases. Indicative values.

Selection

How we define the solution for your process.

We start from what you need to achieve and your facility conditions. We guide you through defining requirements and selecting an appropriate configuration. You do not need to have all this data to start the conversation.

What we evaluate during technical definition
Musts and flow
Number of tanks to be cooled at the same time and flow per circuit.
Temperatures
Target fermentation temperature and the local wet bulb during the harvest.
Location
Outdoor space near the tank room and water available for the evaporative circuit.

FAQ

What clients usually ask us

What outlet temperature does it reach?

On hot February days, at full load, it works with outlet temperatures of 21 to 23 °C. From mid-March, with cooler days, capacity rises and 15 to 18 °C can be reached.

How many musts does it cool at once?

Two, or three depending on the model. Each circuit works with its own must and has thermometers at the inlet and outlet.

Documentation

Technical documentation.

Browse reference brochures for each series. To select equipment, request the configuration and specifications for your project.

Request technical documentation

Engineering and integration

Scope is defined with you.

From equipment selection to integration, installation, and commissioning, we agree on what the project needs and how it connects to your facility. Control systems and after-sales service are integral parts of that conversation.

What we can undertake
Chat on WhatsApp