Compact units and condensing units
Compact refrigeration units / BLOCK
Compact refrigeration units from 3 to 20 HP for cold rooms, tunnels and enclosures at high, medium and low temperature.

Applications
What it solves.
The BLOCK series brings together simple, robust, low-maintenance units to refrigerate or air-condition an enclosure. They are built as MONO-BLOCK units, mounted directly on the cold room wall, and BI-BLOCK units, with the condensing unit separate from the evaporator. FRIMONT selects each unit with its calculation and simulation tools and, for special applications, configures the design to meet the psychrometric, energy or process targets.
- Storage rooms for fresh and chilled products (FBA series, 5 to 20 °C).
- Rooms for chilled product close to 0 °C (FBM series, −5 to +5 °C).
- Frozen storage rooms and tunnels (FBB series, −30 to −15 °C).
- Rooms and enclosures that need dedicated air conditioning or refrigeration.
Configurations
A configuration tailored to your application.
Technical selection defines the equipment and its integration with the process.
FB1 · MONO-BLOCK
The complete unit is mounted directly on the enclosure wall. Direct, simple installation with no refrigerant piping to run on site.
FB2 · BI-BLOCK
The condensing unit is installed separately from the evaporator or air cooler. Each part can go where it works best, and the series' largest models are BI-BLOCK.
FBC · Condensing units
Versatile condensing units to connect to evaporators in general applications.
FBL · Microchillers
Low-capacity liquid chillers for general and special applications.
Construction and control
Scroll (-CS) or semi-hermetic (-RC) compressors from 3 to 20 HP depending on the application. TURBO-design condensers make the most of the airflow to condense at low temperature, and evaporators are matched to get the best out of the compressor.
XSD control
- Dual display with 16 icons: machine status at a glance and the main functions with a single button.
- Up to two remote panels up to 150 m from the unit.
- RS485 serial output with MODBUS protocol for local or internet SCADA monitoring, with variable logging.
Technical data
Reference values.
Series by temperature range
Nominal capacity at each series' standard condition, with 30 °C outdoor air.
| Series | Room temperature | Standard condition | Compressor | Nominal capacity |
|---|---|---|---|---|
| FBA · high | 5 to 20 °C | Room at 10 °C | 3 to 20 HP | 7.1 to 39.0 kW (6.1 to 33.5 Mcal/h) |
| FBM · medium | −5 to +5 °C | Room at 0 °C | 3 to 13 HP | 6.6 to 25.6 kW (5.7 to 22.0 Mcal/h) |
| FBB · low | −30 to −15 °C | Room at −20 °C | 3 to 13 HP | 3.2 to 12.6 kW (2.7 to 10.8 Mcal/h) |
The largest models (FBA from 16.7 kW and FBM from 21.0 kW) are built as BI-BLOCK only. Full per-model tables are in the series brochure.
Selection
How we define the solution for your process.
We start from what you need to achieve and your facility conditions. We guide you through defining requirements and selecting an appropriate configuration. You do not need to have all this data to start the conversation.
What we evaluate during technical definition
- Enclosure and product
- Dimensions, insulation, stored product, daily intake volume, and incoming temperature.
- Daily operation
- Target temperature, operating hours, door openings, and work cycles.
- Installation and monitoring
- Wall-mounted MONO-BLOCK or BI-BLOCK with a separate unit, outdoor space, power supply and required monitoring.
Documentation
Technical documentation.
Browse reference brochures for each series. To select equipment, request the configuration and specifications for your project.
Request technical documentationEngineering and integration
Scope is defined with you.
From equipment selection to integration, installation, and commissioning, we agree on what the project needs and how it connects to your facility. Control systems and after-sales service are integral parts of that conversation.
What we can undertake