Compressors and compression units
Frascold semi-hermetic reciprocating compressors
FRIMONT distributes Frascold, an Italian manufacturer of semi-hermetic compressors, and selects and integrates its compressors into each unit. Semi-hermetic reciprocating compressors for commercial and industrial refrigeration, process cooling and air conditioning, with series for CO₂, hydrocarbons, HFOs and HFCs.
This page follows Frascold's series presentation (frascold.it), adapted to the FRIMONT site. Ranges are catalog data.

Configurations
A configuration tailored to your application.
Technical selection defines the equipment and its integration with the process.
Synthetic refrigerants and hydrocarbons

Standard series
Frascold's most versatile series: quiet operation and small dimensions for tight spaces, in sizes A, B, D, Q, S, V, W and Z.
Catalog data
- Displacement: 4 to 239 m³/h
- Motor power: 0.4 to 59.7 kW
- Refrigerants: HC, HCFC, HFC, HFO and HFO blends

Two-stage
For low temperature with high cooling capacity. It has no external pipes and adds an extra liquid injection system, which increases reliability.
Catalog data
- Displacement: 20.7 to 179.35 m³/h
- Motor power: 3 to 48.5 kW
- Refrigerants: HCFC and HFC
- Sizes S, V, W and Z
CO₂

Subcritical CO₂ · SK3 series
For systems using CO₂ as a natural refrigerant in a subcritical cycle, such as the low stage of a cascade: low environmental impact and energy savings in the same system.
Catalog data
- Displacement: 1.7 to 47.2 m³/h
- Motor power: 0.5 to 22.4 kW
- Sizes A, D, Q and S

Transcritical CO₂ · TK Heavy Duty series
For single-stage or integrated, booster and cascade transcritical CO₂ systems.
Catalog data
- Displacement: 1.9 to 37.9 m³/h
- Motor power: 2.2 to 37.3 kW
- Sizes D, Q, S and Z
Flammable refrigerants (ATEX)

ATEX for hydrocarbons (HC)
ATEX-certified version of the standard series for hydrocarbons such as propane, with the same reliability, low noise and compact size.
Catalog data
- Displacement: 4 to 239 m³/h
- Motor power: 0.4 to 59.7 kW

ATEX for HFOs and HFCs
ATEX-certified series for mildly flammable HFO and HFC refrigerants, across all temperature ranges.
Catalog data
- Displacement: 4 to 239 m³/h
- Motor power: 0.4 to 59.7 kW
- Refrigerants: HCFC, HFC, HFO and HFO blends

ATEX HT · High-temperature propane
ATEX-certified compressors for R290 (propane), designed for high condensing temperatures, as in heat pumps.
Catalog data
- Displacement: 32.8 to 205.8 m³/h
- Motor power: 5.2 to 52.2 kW
- Sizes S, V, W and Z
Technical data
Reference values.
Catalog ranges by series
| Series | Displacement | Motor power | Refrigerants |
|---|---|---|---|
| Standard | 4 to 239 m³/h | 0.4 to 59.7 kW | HC, HCFC, HFC, HFO |
| Two-stage | 20.7 to 179.35 m³/h | 3 to 48.5 kW | HCFC, HFC |
| Subcritical CO₂ SK3 | 1.7 to 47.2 m³/h | 0.5 to 22.4 kW | CO₂ |
| Transcritical CO₂ TK | 1.9 to 37.9 m³/h | 2.2 to 37.3 kW | CO₂ |
| ATEX HC | 4 to 239 m³/h | 0.4 to 59.7 kW | HC |
| ATEX HFO-HFC | 4 to 239 m³/h | 0.4 to 59.7 kW | HCFC, HFC, HFO |
| ATEX HT | 32.8 to 205.8 m³/h | 5.2 to 52.2 kW | HC (R290) |
Source: Frascold. We select the model by refrigerant and by evaporating and condensing temperatures.
Applications
What it solves.
Frascold builds semi-hermetic reciprocating compressors in eight body sizes (A, B, D, Q, S, V, W and Z) and offers them in series by refrigerant and application: standard, two-stage, subcritical and transcritical CO₂, and ATEX-certified versions for flammable refrigerants. At FRIMONT we select the series and model for the operating conditions and integrate them into condensing units, racks and process equipment.
- Commercial and industrial refrigeration.
- Process cooling.
- Air conditioning.
- Refrigerated transport.
Selection
How we define the solution for your process.
We start from what you need to achieve and your facility conditions. We guide you through defining requirements and selecting an appropriate configuration. You do not need to have all this data to start the conversation.
What we evaluate during technical definition
- Refrigerant and operating conditions
- The series depends on the refrigerant (CO₂, hydrocarbons, HFOs or HFCs) and on the evaporating and condensing temperatures. For low temperature with a large lift, two-stage is the better choice.
- Integration into the unit
- We integrate them into condensing units, refrigeration racks and process equipment, with the controls and protections each installation needs.
Documentation
Technical documentation.
Request technical documentation for the configuration required by your process. Tell us about your application and operating conditions to guide the inquiry.
Request technical documentationEngineering and integration
Scope is defined with you.
From equipment selection to integration, installation, and commissioning, we agree on what the project needs and how it connects to your facility. Control systems and after-sales service are integral parts of that conversation.
What we can undertake