FCX: IEC 61508 and IEC 61511 functional safety.

When a project calls for SIL safety functions, we select the certified controllers and devices for that level and develop the programming and functional safety engineering they require, as part of the FCX system. Each function's level is set by the process risk analysis.

FRIMONT technician next to an FCX control panel in a machine room.

IEC 61508

Functional safety by project

When a project calls for SIL functions, the FCX system adds them with safety controllers and devices certified for that level, separate from process control, with the programming and specialist engineering they require.

  • Safety functions independent from normal process control.
  • Certified safety controllers and devices, of the brand and model the project calls for.
  • Verification of the achieved level (PFD or PFH) for each function, together with functional safety specialists.
  • Safety lifecycle documentation for your client or your audit.

IEC 61511

IEC 61511: functional safety for the process industry.

IEC 61511 brings the principles of IEC 61508 to process plants. IEC 61508 addresses whoever manufactures safety equipment; IEC 61511 addresses whoever designs, integrates, operates and maintains the safety instrumented system on site. In an FCX system, the SIS is built on certified safety equipment, separate from process control, and integrated into plant supervision. Alongside functional safety specialists, we support the full lifecycle, from risk analysis to validation.

  • Safety instrumented system (SIS)

    Sensors, a safety logic solver and final elements such as valves and contactors that carry out each safety instrumented function (SIF), independent from normal process control.

  • Full lifecycle

    From risk analysis to design, validation, operation, maintenance and every modification: safety is sustained for the whole life of the plant.

  • Risk analysis and protection layers

    HAZOP to identify hazards and LOPA to share risk reduction across protection layers. Each SIF and its SIL, from 1 to 3, come from there.

  • Safety requirements specification (SRS)

    Defines what each function does, when and how fast it acts, its SIL and how it is tested. It is the basis for design and validation.

  • Devices and proof testing

    Devices certified to IEC 61508 or justified by prior use, plus proof tests at defined intervals to reveal hidden failures.

  • SIS cybersecurity

    The standard requires a cybersecurity risk assessment of the safety instrumented system and points to IEC 62443 to address it.

Key points

SIL2 is not the same as SL2.

  • They are independent scales

    SIL measures the probability of a dangerous failure; SL measures resistance to an attacker. A controller can be SIL2 and have no cybersecurity protection at all.

  • The standards intersect

    IEC 61508 calls for a threat analysis when malicious action is foreseeable, and IEC 61511 requires a cybersecurity assessment of the safety instrumented system. That is why we design with both standards in view.

  • Safety does not depend on the network

    Safety logic acts without depending on the HMI, the network or remote access, and sits in its own cybersecurity zone.

Applications

Common safety functions.

Some functions that usually require a SIL in industrial and refrigeration plants.

  • High-pressure cutout on compressors and vessels.
  • High-high level in separators and liquid receivers.
  • Ammonia leak detection with shutdown and emergency ventilation.
  • Emergency stops and process interlocks.

Two standards, two risks

IEC 61508 and IEC 62443: how they differ.

IEC 61508 covers functional safety: the system must not fail dangerously. IEC 62443 covers cybersecurity: no one should be able to attack or tamper with it on purpose. They complement each other; one cannot replace the other.

Comparison between IEC 61508 and IEC 62443
AspectIEC 61508IEC 62443
What it protects againstRandom hardware failures and systematic design or software errors.Intentional actions: attacks, unauthorized access, malware and tampering.
Level it definesSIL 1 to 4 (Safety Integrity Level).SL 0 to 4 (Security Level).
How the level is measuredProbabilistic. In low demand mode, SIL1 requires a PFD between 10⁻² and 10⁻¹ and SIL2 between 10⁻³ and 10⁻². In continuous mode, PFH per hour is used.Not probabilistic. It depends on the attacker's capability: SL1 covers casual errors or access, SL2 an intentional attack with simple means, and SL3 and SL4 attackers with resources and specific knowledge of industrial systems.
Typical toolsRisk analysis (HAZOP, LOPA), hardware fault tolerance (HFT), diagnostic coverage, safe failure fraction (SFF) and systematic capability.Zones and conduits, 7 foundational requirements (authentication, integrity, confidentiality, among others) and a secure development lifecycle.
StructureGeneric standard in 7 parts, with sector standards derived from it: IEC 61511 for process and IEC 62061 / ISO 13849 for machinery.Organized by role: asset owner (series 2), integrator (3-2 and 3-3) and product supplier (4-1 process and 4-2 component).

How we define it

From risk analysis to the control panel.

  1. Process risk analysis

    Together with your team and functional safety specialists we identify hazards (HAZOP, LOPA) and define which safety functions are needed and at what SIL.

  2. Cybersecurity assessment

    We divide the installation into zones and conduits and set the target SL for each zone.

  3. FCX architecture

    We separate process control from safety functions and select certified hardware for the required level, of the brand the project calls for.

  4. Verification and documentation

    We verify each function and test the configuration, with the independent assessment each SIL calls for, and deliver the documentation for your client or your audit.

SIL levels are defined and verified for each installation based on its risk analysis.