FCX: IEC 61131-3 programming.
We have spent 30 years developing software-based industrial control. Ten years ago we moved to CODESYS, with object-oriented programming to IEC 61131-3, the international standard for programming controllers, in pursuit of safe and reliable systems: orderly, reusable code that runs on the hardware each project calls for.

Object orientation
Programmed with objects.
Object-oriented programming, introduced in the third edition of IEC 61131-3, organizes the software like the plant: equipment with its own logic, variants that inherit what they share and tasks with defined timing.
Open standard
Languages and structure are defined by the standard, not by a brand: the control can be read and maintained without depending on a hardware vendor.
Each machine, an object
Compressors, pumps, valves, heat exchangers and conveyors are programmed as objects with their own logic. They are tested once and reused in every plant.
Inheritance and interfaces
Equipment variants inherit what they share and add what is specific: expanding the plant does not mean rewriting the control.
Deterministic tasks
The program is organized in tasks with a defined cycle and priority, so each part of the process responds on time.
Strictly typed data
Defined types and ranges catch out-of-place values at design time, not in the plant.
A base for secure software
Modular code under strict version control, traceable and verifiable, as functional safety and cybersecurity standards call for. Each project can add new objects and its own programming.
Languages of the standard
One standard, several languages.
IEC 61131-3 defines textual and graphical languages for programming controllers. For each part of the program we use the one that expresses it best and that its maintainers understand best.
Structured Text (ST)
High-level textual language for calculations, algorithms and the logic of each object.
Ladder Diagram (LD)
Relay logic in graphical form, familiar to electricians and maintenance technicians.
Function Block Diagram (FBD)
Blocks wired like a circuit, for control loops and interlocks.
Sequential Function Chart (SFC)
Steps and transitions for start-up and shutdown sequences and batch processes.
CODESYS
One environment, the hardware each project calls for.
CODESYS is an IEC 61131-3 programming environment that runs on controllers and industrial PCs from hundreds of manufacturers, and on virtualized servers too. FCX software does not tie the plant to one brand.
- Controllers and industrial PCs of the brand and model the project calls for.
- EtherCAT, PROFINET, EtherNet/IP and Modbus fieldbuses.
- Virtualized control in containers or on a hypervisor.
- Users, encrypted communication and a protected application on the controller.
- Strict version control of the software.
- SIL safety functions on certified controllers, when the project calls for them.
Hardware and control architecture are defined for each project.
