Skip to main content
FRIMONT SA, home
← All products

Water treatment

Chemical-free industrial water treatment · FIONER

Clean water, free of algae and scale, in large tanks and industrial circuits, with no biocides or additives.

Keeping water in condition used to be costly and demanded constant attention. With the ionic input of FIONER, developed by FRIMONT, water stays in condition with lower consumption, less blowdown and no chemicals to handle.

FIONER dispenser for industrial water treatment
FIONER dispenser, installed in line.

Applications

What it solves.

Water exposed to heat, air and nutrients grows algae, bacteria and biofilm; water that evaporates or heats up deposits carbonates. FIONER treats the water from the circulation pipe and regulates blowdown so the circuit runs at higher cycles of concentration.

  • Large service water tanks and reservoirs.
  • Open process cooling water circuits.
  • Heat exchangers running on hard water.
  • Cooling towers and evaporative condensers.

Configurations

A configuration tailored to your application.

Technical selection defines the equipment and its integration with the process.

Algae, fungi and biofilm

Eliminated in the water and wherever there is liquid water, once the required treatment intensity is reached. Without biofilm, bacteria lose the shelter biocides cannot reach.

Bacteria, viruses and Legionella

Full or partial elimination depending on the selected electrode. Helps prevent Legionella and other infections.

Carbonate scale

Prevents new deposits and slowly breaks down existing limescale, with no acid descaling treatments.

Water and effluent savings

With automatic blowdown and higher cycles of concentration, make-up water and effluent volume go down.

Safety and maintenance

No chemicals on site: no handling, no storage and no corrosion from chlorine or acids.

In operation

  • Non-toxic and non-irritant to people.
  • Not aggressive to metals.
  • The dispenser needs no maintenance; the electrode kit is swapped on the spot.
  • Only an acceptable pH, between 7 and 8, is required.

Technical data

Reference values.

Traditional chemical treatment and FIONER

AspectChemical treatmentFIONER
Biological controlBiocides dosed periodically; they do not reach bacteria sheltered in biofilm and under scale.Continuous ionic input; eliminates biofilm wherever there is liquid water.
ScaleAnti-scalants and periodic acid cleaning.Prevents new deposits and breaks down existing ones.
ConsumablesConstant replenishment: part of the additives is lost with every blowdown.No additives; only the electrode kit is replaced.
MetalsChlorine and acids call for added corrosion inhibitors.Not aggressive to metals.
SafetyChemical handling and storage.Non-toxic and non-irritant.
BlowdownManual or continuous.Automatic, controlled by FIONER.

FIONER series

Reference values by model.

ModelNominal diameterOverall lengthMaximum flowVolume treated
3123 in300 mm58 m³/h4,003 m³
4164 in400 mm100 m³/h6,990 m³
5165 in400 mm163 m³/h8,870 m³
5205 in500 mm163 m³/h12,812 m³
5305 in750 mm163 m³/h22,668 m³
6206 in500 mm227 m³/h11,684 m³
6306 in750 mm227 m³/h22,306 m³
6406 in1,000 mm227 m³/h32,928 m³
8308 in750 mm385 m³/h25,233 m³
8408 in1,000 mm385 m³/h37,248 m³
8608 in1,500 mm385 m³/h61,279 m³
104010 in1,000 mm636 m³/h42,043 m³
106010 in1,500 mm636 m³/h69,167 m³
108010 in2,000 mm636 m³/h96,292 m³
164016 in1,000 mm1,852 m³/h71,515 m³
166016 in1,500 mm1,852 m³/h117,953 m³
168016 in2,000 mm1,852 m³/h164,391 m³

Final selection depends on the equipment, the recirculation flow and the water analysis.

Basin of a unit treated with FIONER: scale comes out as soft sludge.

Selection

How we define the solution for your process.

We start from what you need to achieve and your facility conditions. We guide you through defining requirements and selecting an appropriate configuration. You do not need to have all this data to start the conversation.

What we evaluate during technical definition
Annual use
FIONER pays off when the circuit operates more than 3 months a year.
Circuit and flow
Water volume, recirculation flow and pipe diameter set the series and the dispenser length.
Water quality
Make-up water analysis, with no prior chemical treatment (softened water is fine), and pH between 7 and 8.
Installation
Power supply, control panel location (preferably indoors), level control and a blowdown discharge point.

Documentation

Technical documentation.

Request technical documentation for the configuration required by your process. Tell us about your application and operating conditions to guide the inquiry.

Request technical documentation

Engineering and integration

Scope is defined with you.

From equipment selection to integration, installation, and commissioning, we agree on what the project needs and how it connects to your facility. Control systems and after-sales service are integral parts of that conversation.

What we can undertake
Chat on WhatsApp