FCX: IEC 62443 industrial cybersecurity.
Process control and supervision configured to IEC 62443 for SL1 and SL2, from the operator screen to the controller. The target level is set by the installation's risk assessment and your client's requirements.

IEC 62443
SL1 and SL2 cybersecurity
We configure FCX following the IEC 62443-3-3 system requirements. The target level, SL1 or SL2, comes from the installation's risk assessment.
- Kiosk-mode operation with an unprivileged account and no access to the system.
- Up to 10 user levels and unlimited users per level, as your plant needs.
- On the controller, users with defined permissions, encrypted communication and a protected application.
- Firewall that blocks all incoming traffic except the ports the process needs.
- Authenticated maintenance access, with automatic blocking after failed attempts.
- Minimal software, plus boot and access logging for traceability.
IEC 62443 in FCX
The 7 foundational requirements, applied.
IEC 62443 organizes industrial cybersecurity into seven foundational requirements (FR). This is how we address them in FCX.
- FR 1 Identification and authentication control
- Maintenance access requires authentication and automatically blocks repeated failed attempts. The operator account does not allow password login. On the controller, each user has defined permissions.
- FR 2 Use control
- Operators work with an unprivileged account, on a kiosk-mode screen that gives no access to the system. Up to 10 user levels, with unlimited users per level, so each person sees and operates only what is theirs.
- FR 3 System integrity
- Read-only base system, software reduced to the minimum and an isolated interface where nothing can be added or installed. The controller application is protected against unauthorized changes.
- FR 4 Data confidentiality
- Operator interface over HTTPS and encrypted communication with the controller, with no telemetry, no sync and no external accounts.
- FR 5 Restricted data flow
- All incoming traffic blocked by default; only the ports the process needs are enabled, within the plant's zones and conduits.
- FR 6 Timely response to events
- Installation, boot and access logging, and automatic blocking of sources that try to force access.
- FR 7 Resource availability
- Memory without swap and with a guaranteed reserve, no suspend or hibernation, and automatic restart of the interface after a failure.
How we define it
From risk assessment to configuration.
Risk assessment
Together with your team we divide the installation into zones and conduits and set the target SL for each zone.
FCX architecture
We segment networks, define firewalls and access, and configure users, permissions and encrypted communication on screens and controllers.
Verification and documentation
We test the configuration against the target level's requirements and deliver the documentation for your client or your audit.
The SL is defined and verified for each installation based on its risk assessment.
