Skip to main content
FRIMONT SA, home
Illustrative image of large buildings and infrastructure.

Thermal systems for large buildings and infrastructure

Centralized HVAC for commercial buildings, hotels, and shopping centers, focusing on reliability, efficiency, facility integration, and certification requirements such as LEED.

Tell us about your project

Illustrative image

Understand the process.
Define the solution.

Centralized HVAC must respond to building occupancy, usage patterns, and existing infrastructure. In retrofit projects, access conditions and compatibility with existing systems are just as critical as selecting new equipment. In buildings pursuing LEED certification, the thermal plant also drives prerequisites and credits: refrigerants, efficiency, metering and cooling tower water.

Applications and requirements

Cooling system retrofit

Replacement and upgrading of cooling towers and associated air conditioning equipment, with coordinated engineering and erection.

Chilled water plants

Evaluation of chilled water generation and heat exchange to meet large-scale climate control demands.

Integration and commissioning

Coordination of mechanical connections, electrical installations, and performance verification for the modified scope.

LEED certification

Thermal plants for LEED-certified buildings

LEED, the U.S. Green Building Council's building certification system, also rates HVAC. In version 5, the chilled water plant —chillers, cooling towers, pumps and controls— plays a part in mandatory prerequisites and in credits that earn points: energy efficiency, commissioning, energy and water metering, refrigerant management and cooling tower water use.

We address it through engineering: low-charge chillers with natural refrigerants, heat recovery, cooling towers with water management, and supervision that measures what LEED asks to measure. We give the project's LEED consultant the information they need: refrigerant inventory, tests, measurements and start-up documentation.

We have already applied it at a LEED-certified fresh and frozen food distribution center in Santiago, Chile, which cools all of its rooms with aqueous solutions and holds only 300 liters of ammonia.

LEED v5 reference GWP for HVAC
700
GWP of ammonia, CO₂ and propane
0 to 3
of ammonia at a LEED distribution center
300 L
LEED-certified distribution center in Santiago, Chile: all cooling with aqueous solutions and 300 liters of ammonia.

How the thermal plant answers LEED v5

Indicative summary of the LEED v5 Building Design and Construction (BD+C) requirements related to building HVAC.

LEED v5 requirementWhat it asks forHow we address it
Refrigerant management (prerequisite and credit)Inventory of refrigerant type, GWP and charge for every unit, with no HCFCs in new equipment. The credit earns points when the average GWP is 80% or 50% of the benchmark (700 for HVAC) or, depending on the rating system, for limiting leaks.Low-charge chillers with ammonia or propane, or another low-GWP refrigerant the project requires; factory-assembled units, leak detection and a refrigerant management plan.
Energy efficiency (prerequisite and credit)Meet ASHRAE 90.1 as a minimum and improve performance over that baseline to earn points.Chillers, pumps and tower fans with variable speed drives, optimized water temperatures and plant control that follows the actual load.
Electrification (credit)Points for efficient electric space and water heating instead of fuels.Recovery of condensing heat from the cooling plant for hot water or space heating, which reduces boiler use.
Commissioning and energy metering (prerequisites)Commission HVAC and its controls, and meter building energy with sub-metering of systems such as HVAC, per ASHRAE 90.1.Electrical and thermal metering of the plant integrated into FCX supervision, test protocols and start-up documentation.
Cooling tower water (prerequisite and credit)Makeup water meter, conductivity controller, overflow alarm and efficient drift eliminators. The credit earns points for more cycles of concentration, for lower consumption against a baseline, or for non-potable makeup water.Towers with high-efficiency drift eliminators, conductivity-controlled blowdown and makeup metering; water treatment with the FIONER ionizer or reverse osmosis to run more cycles.

Exact names, points and requirements vary by rating system (BD+C for new construction or major renovations, O+M for existing buildings) and are confirmed by the project's LEED consultant. FRIMONT does not certify the building: we design and build the plant to meet the prerequisites and contribute to the credits the project is pursuing.

See refrigeration systems for LEED projects

Documented experience

Engineering in practice.

Cooling towers and steel structure on the Alto Rosario rooftop

IRSA - Alto Rosario

Cooling tower retrofit at Alto Rosario

Comprehensive retrofit of the Alto Rosario cooling system: engineering, facility adaptation, installation, and commissioning.

View project

Before selecting equipment

Decisions that guide the project

Your operational conditions define the design. These are the key aspects to review from the start.

  • Building use and occupancy profile
  • Condition of existing equipment and piping networks
  • Access routes, mechanical rooms, and erection constraints
  • Construction windows and operational requirements
  • Target LEED certification and credits the thermal plant can contribute to

Tell us what you need to solve.

Do you need to upgrade your building's cooling or prepare its thermal plant for LEED?

To get started, you can share:

  • The process or facility and its location.
  • Current situation and project objective.
  • Existing equipment and available operating data.
  • Current stage and desired scope.

You do not need a complete RFP to start a conversation.

Tell us about your project

A clear scope,
from the beginning.

We can handle a single stage or integrate multiple disciplines. Frimont's scope of responsibility and deliverables are defined for each project.

Conceptual and detail engineering

Facility retrofits and equipment erection

Electrical installations and commissioning according to scope

Refrigerant inventory, measurements and documentation for LEED commissioning

Learn about our capabilities

Equipment and applications

Explore by product.

Options to evaluate based on your process conditions.

FRIMONT air-conditioning chiller with ten condenser fans

Chillers for air conditioning

Chilled water for central air-conditioning systems in large buildings, industrial halls and industrial plants.

Explore equipment
Industrial machine room with compressors and stainless steel vessels

Refrigeration systems for LEED projects

Industrial refrigeration for LEED-certified buildings and distribution centers: natural refrigerants, minimum charge and cooling through aqueous fluids.

Explore equipment
FIONER dispenser for cooling tower water treatment

Cooling tower water treatment · FIONER

Control algae, biofilm and scale in cooling towers and evaporative condensers without dosing biocides or chemicals.

Explore equipment
Industrial refrigeration: view the overview
Chat on WhatsApp