Refrigeration systems and product chilling
CTI gas detection controllers
FRIMONT distributes CTI (Calibration Technologies, United States), a gas detection manufacturer. We build its panels into our plants and also supply them as a stand-alone safety project. Panels that receive the detector signals, show concentrations, log events and drive alarms, ventilation and shutdowns.
This page follows CTI's product presentation (ctigas.com), adapted to the FRIMONT site. Data are catalog figures.

Configurations
A configuration tailored to your application.
Technical selection defines the equipment and its integration with the process.

EM2 · Entrance monitor
Shows the concentration before entering a hazardous room such as a machinery room, and works as a single-channel controller. It sits in series with the detector signal or works on its own.
Catalog data
- 1 channel, 4-20 mA input and output
- 1 SPDT relay
- IP68 polycarbonate enclosure
- Operates from −40 to +50 °C

GG-2 · Two channels
Two-channel controller for small installations, with power for the detectors and for horns and strobes.
Catalog data
- 2 × 4-20 mA inputs
- 6 × 10 A relays: horn, fault and two levels per channel
- 10,000-event log
- NEMA 4X fiberglass enclosure

GG-6 · Up to 30 detectors
The full controller for machinery rooms: six channels expandable to thirty with expansion modules, three alarm levels plus TWA and STEL averages, and optional Ethernet output.
Catalog data
- 6 × 4-20 mA inputs, expandable to 30
- 6 SPDT relays, plus 8 per expansion module
- 10,000-event log
- NEMA 4X enclosure

M255 · Modbus network
Panel with a 10″ color touchscreen for large plants: up to 255 detectors on a Modbus network plus 8 analog inputs, with programmable triggers per detector or group for alarm and ventilation.
Catalog data
- 255 Modbus RTU devices on 4 RS-485 channels
- 8 × 4-20 mA inputs
- 8 Form C relays, 8 A
- Up to 4 groups for alarm and ventilation
Technical data
Reference values.
CTI controllers
| Model | Detectors | Inputs | Relays |
|---|---|---|---|
| EM2 | 1 | 4-20 mA | 1 |
| GG-2 | 2 | 4-20 mA | 6 |
| GG-6 | 6 to 30 | 4-20 mA | 6, plus 8 per module |
| M255 | Up to 255 + 8 | Modbus RTU and 4-20 mA | 8 |
Source: CTI (ctigas.com). 2-year warranty.
Applications
What it solves.
CTI controllers bring a plant's detectors together into a safety system of its own: from a single-channel monitor at the entrance of a room to a touchscreen panel for hundreds of detectors on a Modbus network. Each one logs events and alarms, and its relays drive horns, strobes, emergency ventilation and shutdowns. At FRIMONT we build the complete system and link it to the FCX control when the plant uses it.
- Machinery room detection systems.
- Plants with many rooms and detectors.
- Warning at the entrance of hazardous rooms.
- Expansion of existing detection systems.
Selection
How we define the solution for your process.
We start from what you need to achieve and your facility conditions. We guide you through defining requirements and selecting an appropriate configuration. You do not need to have all this data to start the conversation.
What we evaluate during technical definition
- Number of detectors and growth
- For a few points a GG-2, or an EM2 per room, is enough; the GG-6 covers a machinery room with room to grow, and the M255 fits plants that add many Modbus detectors, such as the GasMark M1.
- Actions on alarm
- We define what each level triggers: warning, horn and strobe, emergency ventilation and equipment shutdowns, and how the plant control is informed.
Documentation
Technical documentation.
Request technical documentation for the configuration required by your process. Tell us about your application and operating conditions to guide the inquiry.
Request technical documentationEngineering and integration
Scope is defined with you.
From equipment selection to integration, installation, and commissioning, we agree on what the project needs and how it connects to your facility. Control systems and after-sales service are integral parts of that conversation.
What we can undertake